High torque electric motor
Test Voltage: 12VDC/24VDC
No load current: < 2.5A
No load speed: 63(+/-7)rpm
1.8NM Rated current: < 7.0A
1.8NM Rated speed: 48-64rpm
6NM Rated current: <12A
6NM Rated speed: 22-41 rpm
Stall torque: 11-14.5NM
Stall current: <24A
1. Resistance between insulated metals in a cold state motor can be larger than 1MΩ measured by a 500V insulation resistance
2. Surface treatment of a motor can suffice the corrosion resistance
3. The performance and drawing of motor is indicated in an approved drawing.
4. The motor can not rotate in reverse direction when it is applied 150kg.cm(14.7NM) torque.
5. Circuit breaker characteristic: a first trip(operation) time is 4-30 sec, and resume time is less than 20sec. A voltage drop in a circuit breaker is smaller than 0.03V/A
6. The noise of motor is less than 60DB, when the distance between motor and noise tester is 30cm, and the background noise is less than 40DB.
7. Water resistance: While water is sprinkled on a motor with water spray volume of 200-250cc/min, the motor should be operated for 1 hour and stop for 11 hours and such operation should be repeated 60 times continuously. After test, there is no infiltration of water.
8. Vibration resistance: Vibration test according to JIS D1601(stage 4) is made in 3 direction for 4 hours vertically, and for each 2 hours laterally and longitudinally, and during the vibration test voltage should not be applied to motor. After test,a variation of output characteristic is 20% or less of the condition before the test.
High torque electric motor
High torque electric motor
xi